Downtime Narrowly Averted with Faulty SCR Drilling DC Drive

In December 2002, on a rig in the GOM, an unusual SCR drilling drive issue occurred. A small amount of AC ripple on a weak power supply caused rapid and uneven wear in the DC motor brushes. Fortunately, the situation did not result in downtime but could have quickly progressed to damage a mud pump DC motor sufficiently to require its replacement.

Faulty SCR - Full Description and Solution

What's New?

WEST now works with operators on a pre-hire assessment to include NPT analysis and rig document reviews. WEST has worked directly with the contractors on these assessments resulting in complete rig information with little disturbance to the operator.